WIBU Wibu Errors "WIBU-KEY error 7 is occurred" or "The accessed WIBU-BOX is not ready (timeout)(7)." or "Virus Check failed!" or "The program needs WIBU-BOX with 250275:123."

A Parallel WIBU Box sporadically displays the errors: "WIBU-KEY error 7 is occurred" or "The accessed WIBU-BOX is not ready (timeout)(7)." or "Virus Check failed!" or can not be recognized despite correctly installed drivers "The program needs WIBU-BOX with 250275:123."

Some notebooks and "newer" PCs don't supply the LPT interface with enough power. This can cause a Timeout problem where the WIBU-KEY driver can not access the WIBU-BOX within the expected time interval.

The time interval can be increased by using a DelayFactor. The Delay Factor can be changed by:

1. Open the Windows Control Panel.
2. Double-click on the WIBU-KEY Program group.
3. Select the 'Setup' tab.
4. Highlight the parallel port the key is attached to in the list on the left.
5. Enter a value for Delay Factor on the lower right.
6. Click Apply and then click OK. NOTE: Start with smaller values of Delay Factor first (1-4). The larger you make the value for delay factor, the longer it will take for EASYLABEL to open.