Blank Screen Due to Number of Fields

Any format designed to have 490 fields causes EASYLABEL to display a blank screen instead of the operator input boxes when the format is selected for printing.  If the user elects to print the format definition for this particular format, the screen shows empty boxes where the format specification information should be. This then causes EASYLABEL to lock up. When fields are removed so that the total number of fields on the format is down to 350, the operator input boxes re-appear when the format is selected for printing.

There is a limitation as to the number of operator input boxes that can be displayed within a window. The limitation is based on the screen resolution and the number of pixels required to draw items in a window.

The best case is to use a screen resolution of 640x480. The lower the display resolution, the greater the number of fields EASYLABEL is able to draw when displaying the operator input window on the print menu.